Upgrade Information for MIMI Module 3/22/2004 Release Version 3.3 Tested in IDL 5.4 on Linux Lemms priority counters in both very low and the other telemetry modes now work in line plots, spectrograms and the priority plots. All modules have code to allow them to be read on VAX, Unix and windows platforms. Inca TOF channel plots now use the most recent INCA calibration data. 3/16/2004 Release Version 3.2 Changes: Added OS check to set the proper directory delimiter so should work on windows. Tested with Papco 10.0 and IDL 5.4 3/9/2004 Release Version 3.1 Changes: These modules have been tested with Papco Version 10.0 and IDL 5.4 LEMMS, CHEMS and INCA read routines now look for IDL save sets from a ftp site at JHU Applied Physics Laboratory, ftp://mimipap@sd-ftp.jhuapl.edu/papdata_v35, after looking in the normal on site path for the files. NOTE: The data path that you set in the config part of each menu should be the location of your data minus the four digit year subdirectories that the software will append to the data directory. Please don't forget to make the year directories under the data path. ex. config directory /project/cassini/data/lemmsrates software looks in /project/cassinl/data/lemmsrates/2004 The LEMMS module was changed to read the MIMI L1a Version 35 files which contain 6 priority counters now. The menus were changed to allow selection of the new priority channels and based on the time selected, the proper names will appear. If priority channels 4 and 5 are selected for times when those channels were not loaded, (before 2003-255), the plots will appear but will contain fill data. Known Problem: There is currently a bug for the LEMMS data at very low data rate in the priority plot routine. The CHEMS module was changed to the MIMI L1a Version 35 files and now uses a fill value of 65535ll. Known Problem: Some of the 1999 and 2001 data did not read correctly and this bug will be fixed in the next version. The INCA module tof now reads the L1b files which are calibrated to differential flux. The options for counts, and integral flux were removed from the menu. Example Papco plot files, *.papco, were included with the modules. 3/9/2004 Release Version 3.0 Changes: LEMMS, CHEMS and INCA read routines now look for IDL save sets from a ftp site at JHU Applied Physics Laboratory, ftp://mimipap@sd-ftp.jhuapl.edu/papdata_v35, after looking in the normal on site path for the files. LEMMS changed to read the MIMI L1a Version 35 files which contain 6 priority counters now. The menus were changed to allow selection of the new priority channels and based on the time selected, the proper names will appear. If priority channels 4 and 5 are selected for times when those channels were not loaded, the plots will appear but will contain fill data. There is currently a bug for the LEMMS data at very low data rate in the priority plot routine. This will be fixed in the next release. CHEMS was changed to the MIMI L1a Version 35 files and now uses a fill value of 65535ll. INCA tof will be released in the next version. 5/9/2003 Release Version 2.0 Changes: Environmental Variables were changes to refer to a path under which a subdirectory must reside. For example: CASSINI_MIMI_LEMMS_DATA = "/project/cassini/serv1/data_L1a/lemmsrates/" and the data should reside in, /project/cassini/serv1/data_L1a/lemmsrates/1999 /project/cassini/serv1/data_L1a/lemmsrates/2000 /project/cassini/serv1/data_L1a/lemmsrates/2001 LEMMS, CHEMS and INCA read routines now look for IDL save sets from a ftp site at JHU Applied Physics Laboratory after looking in the normal on site path for the files. LEMMS IDL save sets now contain the priority counters as well as the normal counters so you can not use the old save sets anymore with version 2.0 New Features: Papco FTP site at JHU Applied Physics Laboratory has been created and is being populated with IDL save sets for LEMMS, CHEMS and INCA sensors. LEMMS accumulator rates plots now allow the selection of the priority counters for plotting. The LEMMS turntable clock angle plot is now available. INCA time-of-flight line plots are now available in counts, integral and differential flux. 3/19/2002 Release Version 1.0 Fixes for: Decreased plotting time for CHEMS and LEMMS modules. Added Papco plotting product files for CHEMS spectrums, LEMMS accumulator rates and LEMMS spectrum. Created a data set of MIMI CHEMS and LEMMS IDL save sets. 2/8/2002 Release Version 0.0 (Sebastian Bourdarie) LEMMS Accumulator Rates, CHEMS Basic and Science Rates Line Plots and Spectrums