MIMI Monthly Plot Directions:
1. Select the plot style by clicking on the desired style.
2. Select black or white background.
2. Enter the year and day of year.
3. Select Update Window button to display the selected plot.
4. The plots have 1 page per month.
6. The << button will page down the amount in days, the >> button will page up the amount in days. The
default is 28 days.
MIMI Plot Descriptions
INCA TOF Channels:
The INCA TOF channel plot displays the high time-of-flight resolution image data averaged over 4 images and then averaged to one value per image and plotted as line plots on a logarithmic scale in differential flux.
Spacecraft Orientation:
The top plot is of the Z spin flag that will plot a green line if it is set to 1 (MIMI in spin mode).
The other plots list angles in degrees 0 - 180 from the s/c axis to NEP, Sun and planet. The data closest to 0 and 180 should stand out.
Axis | Degrees | Color |
-X | 90-180 | blue |
| 0 - 89.9 | red |
-Y | 90-180 | gray |
| 0 - 89.9 | orange |
-Z | 90-180 | green |
| 0- 89.9 | hot pink |
170-180 | Thick line |
135-169.9 | Medium line |
45-134.9 | Thin line |
10-44.9 | Medium line |
0-9.9 | Thick line |
LEMMS Rates:
The LEMMS rates plot displays the periodic readouts of the accumulator channels from the two telescopes, in counts/accumulator as line plots on a logarithmic scale. It also includes a plot of the priority channels that are sampled more frequently in counts/accumulator on a logarithmic scale. The bottommost plot is a spacecraft orientation plot.
Data Validity:
The top plot displays a thick colored bar if the
INCA instrument is in ion mode (where the collimator voltage is less than a threshold value). If the voltage on the collimator is
outside the normal expected value, a thin bar is plotted.
The rest of the lines in the data validity plot display the L1a data validity
measurements. For most of the data types
this consists of if the data is present. For the auxiliary data the line indicates that the sector start of time
data was present. The auxiliary start of sector time is used in the timing calculation for all the data types except for housekeeping.
Analog Converted Volts:
The analog converted voltages plot displays the more important voltages in volts on linear scale line plots.
Analog Converted Currents:
The analog converted currents plot displays the more important currents in milliamps respectively on linear scale line plots.
Analog Converted Temps:
The analog converted temperature plot displays the more important instrument temperatures in degrees Centigrade and valid and invalid command counts on linear scale line plots.
Processing Products:
The processing products page lists the L0, L1a, kernels and browse products produced by the processing
system. The columns are file type, file name, date, file size and the % complete of the supporting data file
for the file type.